Digital Multimeters: Auto Range, Manual Range, Bench

A digital multimeter measures voltage, current and resistance, and most models add capacitance, frequency, temperature or continuity tests. Auto range models pick the measuring range for you, manual range models leave the choice to the user, and bench models give higher resolution for lab and production testing.

Models

  • VC746A 6000-Count True RMS Multimeter, Live and NCV

    VC746A

    VC746A 6000-Count True RMS Multimeter, Live and NCV

    Wide-screen multimeter

    Wide LCD, auto/manual range
    6000 counts
    Non-contact & contact test
    NCV + Live
    High voltage indication
    True RMS
    Max capacitance
    60 mF
    Max AC/DC current
    20 A

    VC746A digital multimeter, available to measure AC/DC voltage, AC/DC current, resistance, capacitance, frequency, contact and non-contact voltage detection, duty cycle, temperature, diodes, and continuity testing. It also features true root mean square (RMS), NCV+Live voltage detection, high-voltage symbol indication, frequency/duty cycle measurement, backlight/flashlight lighting, data hold, low-voltage display, and auto power-off functions.

  • VC835B 2000-Count True RMS Auto Range Multimeter, NCV

    VC835B

    VC835B 2000-Count True RMS Auto Range Multimeter, NCV

    Auto-range multimeter

    Counts, auto ranging
    2000
    Capacitance range
    20 nF–2000 μF
    Frequency range
    10 Hz–1 MHz
    Duty cycle
    1%–99%
    Plus torch, temperature
    True RMS / NCV

    VC835B multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Frequency, Non-contact voltage (NCV) detecting, Duty-cycle, Temperature, Diode and Continuity tests; Designed with unit symbol, Torch lighting, Data hold, Auto ranging switch, Auto power off and alarm functions. 2000 counts display

  • VC89 6000-Count True RMS Multimeter, Pulse Output

    VC89

    VC89 6000-Count True RMS Multimeter, Pulse Output

    Auto range multimeter

    Auto range
    6000 counts
    Pulse + square wave output
    50 Hz–5 kHz
    NCV, REL
    True RMS
    Max capacitance
    60 mF
    Max AC/DC current
    20 A

    VC89 auto range multimeter measures DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, duty cycle and temperature, with diode, hFE and continuity tests. It adds pulse output (50Hz~5kHz) and square wave output, and has True RMS, NCV, REL, backlight, data hold, function protection and auto power off. 6000 counts display.

  • VC834 True RMS Manual Range Multimeter, NCV, Temperature

    VC834

    VC834 True RMS Manual Range Multimeter, NCV, Temperature

    Manual-range multimeter

    DC voltage range
    200 mV–600 V
    Temperature range
    -40–1000 ℃
    Data hold
    Max / Min
    AC measurement / live detect
    True RMS / NCV
    Counts, manual ranging
    2000

    VC834 manual range multimeter measures DC voltage, AC voltage, DC current, resistance and temperature, with diode and continuity tests. It has True RMS, non-contact voltage (NCV) detection, backlight, Max/Min data hold, protection and anti-shock function, low battery indication and auto power off. 2000 counts display, powered by two AAA batteries.

  • VC179 6000-Count True RMS Industrial Multimeter, 1000V

    VC179

    VC179 6000-Count True RMS Industrial Multimeter, 1000V

    Industrial multimeter

    DCV basic accuracy
    ±(0.09%+2)
    DC / AC voltage range
    600 mV–1000 V
    DC / AC current range
    60 mA–20 A
    Counts, True RMS, bargraph
    6000
    Frequency range
    6 Hz–15 MHz

    VC179 1000V industrial multimeter measures DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, duty cycle and temperature, with diode and continuity tests. It has True RMS, NCV, REL, Max/Min data hold, backlit display with analog bargraph, manual and automatic ranging, low battery indication and auto power off. 6000 counts display.

  • VC9807A+ 19999-Count 4.5-Digit High Accuracy Multimeter

    VC9807A+

    VC9807A+ 19999-Count 4.5-Digit High Accuracy Multimeter

    4½-digit multimeter

    4½-digit, manual range
    20000 counts
    DC voltage accuracy
    ±(0.1%+5)
    Conductance
    0.1–100 nS
    DC current, ±(0.5%+4)
    20 A
    Max capacitance
    200 μF

    VC9807A+ multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, capacitance, conductance, frequency, hFE, diode and continuity tests; Designed with unit symbol and backlight display, data hold, auto power off and mis-operation protection functions. 19999 counts display

  • VC732A True RMS Digital Multimeter, NCV, Duty Cycle, hFE

    VC732A

    VC732A True RMS Digital Multimeter, NCV, Duty Cycle, hFE

    Wide-screen multimeter

    Auto or manual range
    2000 counts
    NCV, torch, backlight
    True RMS
    DC voltage, ±(0.5%+5)
    1000 V DC
    Max capacitance
    2000 μF
    Transistor test
    hFE

    VC732A 2000 counts auto range multimeter is available to test DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, Duty-cycle, Temperature, hFE, Diode and continuity tests and with backlight, torch, data-hold functions.

  • VC87 True RMS Multimeter, 10kHz Response, VFD Mode

    VC87

    VC87 True RMS Multimeter, 10kHz Response, VFD Mode

    VSD multimeter

    VSD inverter voltage (TRMS)
    6–750 V
    Analog bar display
    6000 counts
    Max frequency
    30 MHz
    Max AC/DC current
    20 A
    AC response to 20 kHz
    True RMS

    VC87 multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, duty-cycle, temperature, diode, continuity and VSD measurements; Designed with unit symbol , analog bar and backligjt display, max, min tests, data hold, autor ranging switch, auto power and alarm functions. 6000 counts display

  • VC99 True RMS Auto Range Multimeter, Analog Bar, NCV

    VC99

    VC99 True RMS Auto Range Multimeter, Analog Bar, NCV

    Auto range multimeter

    Analog bar display
    6000 counts
    DC voltage, ±(0.5%+5)
    1000 V DC
    Max AC/DC current
    20 A
    Max capacitance
    60 mF
    NCV, Max/Min, REL
    True RMS

    VC99 multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, non-contact voltage detection, duty cycle, temperature, diode and continuity tests; Designed with unit symbol display and analog bar display, max and min value measurement, data hold, auto ranging switch, auto power off and alarm functions. 6000 counts display

  • VC97A 4000-Count True RMS Auto Range Multimeter, NCV

    VC97A

    VC97A 4000-Count True RMS Auto Range Multimeter, NCV

    Auto range multimeter

    Auto or manual range
    4000 counts
    DC voltage, ±(0.5%+5)
    1000 V DC
    Max AC/DC current
    20 A
    Max capacitance
    40 mF
    NCV, Max/Min, REL
    True RMS

    VC97A multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, non-contact voltage detection, duty cycle, temperature, diode and continuity tests; Designed with unit symbol display and maximum and minimum value measurement, data hold, auto ranging switch, auto power off and alarm functions. 4000 counts display

  • VC88 Auto Range Multimeter with TTL Logic and Frequency

    VC88

    VC88 Auto Range Multimeter with TTL Logic and Frequency

    Logic level multimeter

    Auto or manual range
    4000 counts
    Logic level test
    TTL / CMOS
    Max capacitance
    40 mF
    Frequency, duty cycle, REL
    10 MHz
    With NCV, Max/Min hold
    True RMS

    VC88 multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, logic (TTL COMS), temperature, duty-cycle, hFE, Diode and continuity tests; Designed with unit symbol display, data hold, REL test, auto/manual ranging shift, auto power off and alarm functions. 4000 counts display

  • VC86 True RMS Auto Range Multimeter, NCV, Max/Min

    VC86

    VC86 True RMS Auto Range Multimeter, NCV, Max/Min

    Auto-range multimeter

    DC voltage range
    200 mV–1000 V
    DC / AC current range
    200 μA–20 A
    Resistance range
    200 Ω–200 MΩ
    Data hold
    Max / Min
    2000 counts, temperature
    True RMS / NCV

    VC86 multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, non-contact voltage (NCV) detecting, temperature, hFE, Diode and continuity tests; Designed with unit symbol, backlight display, data hold, max value, min value tests, auto ranging switch, auto power off and alarm functions. 2000 counts display

  • VC836 True RMS Auto Range Multimeter, Analog Bar, NCV

    VC836

    VC836 True RMS Auto Range Multimeter, Analog Bar, NCV

    Auto-range multimeter

    No dial changes
    One-key
    Counts, True RMS, analog bar
    6000
    Single current range
    10 A
    Capacitance range
    60 nF–60 mF
    Frequency range
    10 Hz–10 MHz

    VC836 multimeter, automatically tests DC voltage, AC voltage, AC current, AC current, Resistance, Capacitance, Frequency, Non-contact voltage (NCV) detecting, Duty-cycle, Temperature, Diode and Continuity; Designed with unit symbol, torch lighting, data hold, analog bar display, backlight display, auto ranging switch, auto power and alarm functions. 6000 counts display

  • VC837A True RMS Auto Range Multimeter, Analog Bar, NCV

    VC837A

    VC837A True RMS Auto Range Multimeter, Analog Bar, NCV

    Auto-range multimeter

    Counts, True RMS, auto range
    6000
    Trend display under digits
    Analog bar
    DC / AC current range
    600 μA–10 A
    Capacitance range
    60 nF–60 mF
    Frequency range
    10 Hz–10 MHz

    VC837A multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Frequency, Non-contact voltage detecting, Duty-cycle, Temperature, Diode and Continuity tests; Designed with unit symbol, backlight display, analog bar display, torch lighting, data hold, auto ranging switch, auto power off and alarm functions. 6000 counts display

  • VC835A True RMS Auto Range Multimeter with NCV

    VC835A

    VC835A True RMS Auto Range Multimeter with NCV

    Auto-range multimeter

    Counts, auto ranging
    2000
    DC / AC current range
    200 μA–10 A
    Temperature range
    -40–1000 ℃
    Plus torch, backlight
    True RMS / NCV
    HFE transistor test
    0–2000

    VC835A multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Non-contact voltage (NCV), Temperature, hFE, Diode and Continuity tests; Designed with unit symbol, Backlight display, Data hold, Torch lighting, Auto ranging switch, Auto power off and Alarm functions. 1999 counts display

  • VC837 6000-Count True RMS Auto Range Multimeter, NCV

    VC837

    VC837 6000-Count True RMS Auto Range Multimeter, NCV

    Auto-range multimeter

    Counts, True RMS, auto range
    6000
    DC / AC current range
    600 μA–10 A
    Capacitance range
    60 nF–60 mF
    Frequency range
    10 Hz–10 MHz
    Duty cycle
    1%–99%

    VC837 multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Frequency, Non-contact voltage (NCV) detecting, Duty-cycle, Temperature, Diode and Continuity tests; Designed with unit symbol, Torch lighting, Data hold, Auto ranging switch, Auto power off and alarm functions. 6000 counts display

  • VC835 True RMS Auto Range Multimeter with NCV

    VC835

    VC835 True RMS Auto Range Multimeter with NCV

    Auto-range multimeter

    Counts, auto ranging
    2000
    DC / AC current range
    200 μA–10 A
    Temperature range
    -40–1000 ℃
    Plus torch, backlight
    True RMS / NCV
    HFE transistor test
    0–2000

    VC835 multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, non-contact voltage detecting, temperature, hFE, Diode and continuity tests; Designed with unit symbol, backlight display, data hold, torch lighting, auto range switch, auto power and alrm functions. 1999 counts display

  • VC890C Manual Range Multimeter with Shockproof Holster

    VC890C

    VC890C Manual Range Multimeter with Shockproof Holster

    Manual-range multimeter

    DC voltage range
    200 mV–1000 V
    DC / AC current range
    20 μA–20 A
    Temperature range
    -40–1000 ℃
    Capacitance range
    2 nF–200 μF
    Counts, True RMS
    2000

    VC890C multimeter, DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Temperature, Diode and Contunity tests; Designed with unit symbol, data hold, Auto power off and alarm functions. 2000 counts display.

  • VC890D Manual Range Multimeter with Shockproof Holster

    VC890D

    VC890D Manual Range Multimeter with Shockproof Holster

    Manual-range multimeter

    DC voltage range
    200 mV–1000 V
    AC voltage range
    2 V–750 V
    DC current range
    200 μA–20 A
    Capacitance range
    20 nF–200 μF
    Counts, True RMS
    2000

    VC890D multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Diode and Continuity tests; Designed with unit symbol , data hold, auto power off and alarm functions. 2000 counts display.

  • VC9808+ Manual Range Multimeter, Inductance and 2000uF

    VC9808+

    VC9808+ Manual Range Multimeter, Inductance and 2000uF

    Manual range multimeter

    Manual range, peak hold
    2000 counts
    Inductance
    2 mH–20 H
    Max resistance
    2000 MΩ
    Max capacitance
    2000 μF
    Temperature
    -40–1000 ℃

    VC9808+ multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Inductance, Frequency, Temperature, hFE, Diode and Continuity tests; Designed with unit symbol, peak value hold, auto power off and protect function for error operation. 2000 counts display.

  • VC9802A+ Manual Range Multimeter, 200uF Capacitance

    VC9802A+

    VC9802A+ Manual Range Multimeter, 200uF Capacitance

    Manual range multimeter

    Manual range
    2000 counts
    DC voltage, ±(0.5%+3)
    1000 V DC
    Max resistance
    200 MΩ
    Max capacitance
    200 μF
    Max AC/DC current
    20 A

    VC9802A+ multimeter is available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, hFE, Diode anc continuity alarm tests ; Designed with unit symbol, backlight, data hold, auto power off and protection function for error operations. 2000 counts display.

  • VC833A Manual Range Multimeter, True RMS, NCV, Flashlight

    VC833A

    VC833A Manual Range Multimeter, True RMS, NCV, Flashlight

    Manual-range multimeter

    DC voltage range
    200 mV–600 V
    DC current range
    20 μA–10 A
    Counts, manual ranging
    2000
    AC measurement / live detect
    True RMS / NCV
    Plus backlight, data hold
    Torch

    VC833A multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Non-contact voltage detecting, hFE, Diode and continuity alarm tests; Designed with unit symbol, backlight, data hold, torch lighting, auto power off and alarm functions; 2000 counts display.

  • VC833 Manual Range Multimeter, True RMS and NCV

    VC833

    VC833 Manual Range Multimeter, True RMS and NCV

    Manual-range multimeter

    DC voltage range
    200 mV–600 V
    DC current range
    20 μA–10 A
    Counts, manual ranging
    2000
    AC measurement / live detect
    True RMS / NCV
    HFE transistor test
    0–2000

    VC833 multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Non-contact voltage detecting, hFE, Diode and continuity alarm tests ; Designed with unit symbol, backlight, data hold, auto power off and alarm functions;. 2000 counts display.

  • VC8045 19999-Count Bench Multimeter, True RMS AC+DC

    VC8045

    VC8045 19999-Count Bench Multimeter, True RMS AC+DC

    Bench multimeter

    Counts, manual ranging
    19999
    DCV basic accuracy
    ±(0.05%+1)
    AC measurement
    True RMS AC+DC
    AC frequency response
    40 Hz–50 kHz
    DC current range
    20 mA–20 A

    This VC8045 bench type multimeter can measure DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Diode, Triode, Continuity and Frequency. AC voltage and current are measured by high-precision true RMS, which has the characteristics of measuring frequency bandwidth, and accurately measure the RMS of any waveform of AC or AC+DC. 19999 counts display.

The table below lists every Vicimeter multimeter with its main functions.

How to Choose Digital Multimeters

Four decisions narrow this list to two or three models.

  • Voltage and safety rating: the VC83x models (VC833A, VC835B, VC837, VC836) measures to 600V and is rated CAT III 300V, which suits electronics repair and household circuits. For distribution boards and industrial panels, pick a CAT III 600V model that reads 1000V DC, such as VC86, VC97A, VC99 or VC746A.
  • Display resolution: 2000 counts (VC86, VC732A) is enough for mains and battery checks. 6000 counts (VC837, VC99) gives one more digit on low voltages. For component work, VC9807A+ shows 20000 counts with DCV accuracy of ±(0.1%+5), and the mains powered VC8045 bench meter reaches ±(0.05%+1).
  • Ranging style: VC836 measures with one key and no dial changes. VC97A, VC99 and VC88 offer both auto and manual range, useful when an auto range meter keeps hunting on a drifting signal. Manual models such as VC890D and VC9802A+ are listed under manual range multimeters.
  • Special functions: VC87 has a VSD mode for variable frequency drive outputs, VC88 tests TTL/CMOS logic levels, VC746A adds a live contact voltage test, and VC890C measures temperature to 1000℃. If you only need NCV and a torch on a 600V meter, see the auto range multimeters.

Bench Multimeters

ModelKey functions
VC8045Max.19999 counts, High Accuracy Bench Type Multimeter, True RMS, AC +DC measurements, Backlight

Manual Range Multimeters

ModelKey functions
VC834manual range multimeter, True RMS, NCV, temperature, Max/Min data hold
VC890CManual ranging, Max 200uF capacitance, Anti-high pressure ignition design, high-strength anti-drop protection shock-proof holster.
VC890DManual ranging, Max 200uF capacitance test, Anti-high pressure ignition design, High-strength anti-drop protection shock-proof holster.
VC9808+Max 2000uF capacitance, Max 2000MΩ resistance, Inductance, Frequency, Temperature tests, Anti-high pressure ignition design.
VC9802A+Current 200uA, Max 200uF capacitance, Max 200MΩ resistance, Anti-high pressure ignition design.
VC833AManual ranging, True RMS, NCV test, Data hold, Backlight, Torch lighting function.
VC833Manual ranging, True RMS, NCV tests, Data hold, Backlight.

Auto Range Multimeters

ModelKey functions
VC746ALive, NCV, T-RMS tests 6000 counts auto ranging multimeter with Data hold, Duty-cycle, Diode, hFE tests and Data hold, Backlight Torch functions
VC835BMax 2000 counts, True RMS & NCV test, Data hold, Backlight, Torch lighting function, 2024 new protect holster.
VC89auto range multimeter, True RMS, pulse and square wave output, NCV, 6000 counts
VC1791000V industrial multimeter, True RMS, 0.09% DCV accuracy, NCV, analog bargraph
VC732ANCV T-RMS Duty-cycle Diode hFE tests digital multimeter with data-hold, backlight, torch functions
VC87Non-linear True RMS maximum frequency response 10kHz measurement, Frequency conversion measurement, Analog bar display, Max/Min
VC99True RMS, Analog bar display, NCV test, Max/Min , Data hold, Backlight.
VC97AMax 4000 counts, True RMS, NCV Tests, Max/Min, Data hold, Backlight.
VC88COMS, TTL logic level tests, Frequency, Duty-cycle, REL, tests, Data hold, Backlight.
VC86True RMS, NCV tests, Max/Min tests, Data hold, Backlight.
VC836Intelligent True RMS, NCV tests, Analog bar display, Data hold, Backlight, Torch lighting function.
VC837ATrue RMS test, Analog bar display, NCV test, Data hold, Backlight, Torch lighting function.
VC835ATrue RMS, NCV tests, Data hold, Backlight, Torch lighting function.
VC837Max 6000 counts, True RMS & NCV test, Data hold, Backlight, Torch lighting function.
VC835True RMS, NCV tests, Data hold, Backlight, Torch lighting function.

4.5-Digit Multimeters

ModelKey functions
VC9807A+Max 19999 counts high accuracy, Max 200uF capacitance, Frequency, Conductance tests, Anti-high pressure ignition design.

Digital Multimeters Guides