Digital Multimeters: Auto Range, Manual Range, Bench
A digital multimeter measures voltage, current and resistance, and most models add capacitance, frequency, temperature or continuity tests. Auto range models pick the measuring range for you, manual range models leave the choice to the user, and bench models give higher resolution for lab and production testing.
Models

VC746A
VC746A 6000-Count True RMS Multimeter, Live and NCV
Wide-screen multimeter
- Wide LCD, auto/manual range
- 6000 counts
- Non-contact & contact test
- NCV + Live
- High voltage indication
- True RMS
- Max capacitance
- 60 mF
- Max AC/DC current
- 20 A
VC746A digital multimeter, available to measure AC/DC voltage, AC/DC current, resistance, capacitance, frequency, contact and non-contact voltage detection, duty cycle, temperature, diodes, and continuity testing. It also features true root mean square (RMS), NCV+Live voltage detection, high-voltage symbol indication, frequency/duty cycle measurement, backlight/flashlight lighting, data hold, low-voltage display, and auto power-off functions.

VC835B
VC835B 2000-Count True RMS Auto Range Multimeter, NCV
Auto-range multimeter
- Counts, auto ranging
- 2000
- Capacitance range
- 20 nF–2000 μF
- Frequency range
- 10 Hz–1 MHz
- Duty cycle
- 1%–99%
- Plus torch, temperature
- True RMS / NCV
VC835B multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Frequency, Non-contact voltage (NCV) detecting, Duty-cycle, Temperature, Diode and Continuity tests; Designed with unit symbol, Torch lighting, Data hold, Auto ranging switch, Auto power off and alarm functions. 2000 counts display

VC89
VC89 6000-Count True RMS Multimeter, Pulse Output
Auto range multimeter
- Auto range
- 6000 counts
- Pulse + square wave output
- 50 Hz–5 kHz
- NCV, REL
- True RMS
- Max capacitance
- 60 mF
- Max AC/DC current
- 20 A
VC89 auto range multimeter measures DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, duty cycle and temperature, with diode, hFE and continuity tests. It adds pulse output (50Hz~5kHz) and square wave output, and has True RMS, NCV, REL, backlight, data hold, function protection and auto power off. 6000 counts display.

VC834
VC834 True RMS Manual Range Multimeter, NCV, Temperature
Manual-range multimeter
- DC voltage range
- 200 mV–600 V
- Temperature range
- -40–1000 ℃
- Data hold
- Max / Min
- AC measurement / live detect
- True RMS / NCV
- Counts, manual ranging
- 2000
VC834 manual range multimeter measures DC voltage, AC voltage, DC current, resistance and temperature, with diode and continuity tests. It has True RMS, non-contact voltage (NCV) detection, backlight, Max/Min data hold, protection and anti-shock function, low battery indication and auto power off. 2000 counts display, powered by two AAA batteries.

VC179
VC179 6000-Count True RMS Industrial Multimeter, 1000V
Industrial multimeter
- DCV basic accuracy
- ±(0.09%+2)
- DC / AC voltage range
- 600 mV–1000 V
- DC / AC current range
- 60 mA–20 A
- Counts, True RMS, bargraph
- 6000
- Frequency range
- 6 Hz–15 MHz
VC179 1000V industrial multimeter measures DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, duty cycle and temperature, with diode and continuity tests. It has True RMS, NCV, REL, Max/Min data hold, backlit display with analog bargraph, manual and automatic ranging, low battery indication and auto power off. 6000 counts display.

VC9807A+
VC9807A+ 19999-Count 4.5-Digit High Accuracy Multimeter
4½-digit multimeter
- 4½-digit, manual range
- 20000 counts
- DC voltage accuracy
- ±(0.1%+5)
- Conductance
- 0.1–100 nS
- DC current, ±(0.5%+4)
- 20 A
- Max capacitance
- 200 μF
VC9807A+ multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, capacitance, conductance, frequency, hFE, diode and continuity tests; Designed with unit symbol and backlight display, data hold, auto power off and mis-operation protection functions. 19999 counts display

VC732A
VC732A True RMS Digital Multimeter, NCV, Duty Cycle, hFE
Wide-screen multimeter
- Auto or manual range
- 2000 counts
- NCV, torch, backlight
- True RMS
- DC voltage, ±(0.5%+5)
- 1000 V DC
- Max capacitance
- 2000 μF
- Transistor test
- hFE
VC732A 2000 counts auto range multimeter is available to test DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, Duty-cycle, Temperature, hFE, Diode and continuity tests and with backlight, torch, data-hold functions.

VC87
VC87 True RMS Multimeter, 10kHz Response, VFD Mode
VSD multimeter
- VSD inverter voltage (TRMS)
- 6–750 V
- Analog bar display
- 6000 counts
- Max frequency
- 30 MHz
- Max AC/DC current
- 20 A
- AC response to 20 kHz
- True RMS
VC87 multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, duty-cycle, temperature, diode, continuity and VSD measurements; Designed with unit symbol , analog bar and backligjt display, max, min tests, data hold, autor ranging switch, auto power and alarm functions. 6000 counts display

VC99
VC99 True RMS Auto Range Multimeter, Analog Bar, NCV
Auto range multimeter
- Analog bar display
- 6000 counts
- DC voltage, ±(0.5%+5)
- 1000 V DC
- Max AC/DC current
- 20 A
- Max capacitance
- 60 mF
- NCV, Max/Min, REL
- True RMS
VC99 multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, non-contact voltage detection, duty cycle, temperature, diode and continuity tests; Designed with unit symbol display and analog bar display, max and min value measurement, data hold, auto ranging switch, auto power off and alarm functions. 6000 counts display

VC97A
VC97A 4000-Count True RMS Auto Range Multimeter, NCV
Auto range multimeter
- Auto or manual range
- 4000 counts
- DC voltage, ±(0.5%+5)
- 1000 V DC
- Max AC/DC current
- 20 A
- Max capacitance
- 40 mF
- NCV, Max/Min, REL
- True RMS
VC97A multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, non-contact voltage detection, duty cycle, temperature, diode and continuity tests; Designed with unit symbol display and maximum and minimum value measurement, data hold, auto ranging switch, auto power off and alarm functions. 4000 counts display

VC88
VC88 Auto Range Multimeter with TTL Logic and Frequency
Logic level multimeter
- Auto or manual range
- 4000 counts
- Logic level test
- TTL / CMOS
- Max capacitance
- 40 mF
- Frequency, duty cycle, REL
- 10 MHz
- With NCV, Max/Min hold
- True RMS
VC88 multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, logic (TTL COMS), temperature, duty-cycle, hFE, Diode and continuity tests; Designed with unit symbol display, data hold, REL test, auto/manual ranging shift, auto power off and alarm functions. 4000 counts display

VC86
VC86 True RMS Auto Range Multimeter, NCV, Max/Min
Auto-range multimeter
- DC voltage range
- 200 mV–1000 V
- DC / AC current range
- 200 μA–20 A
- Resistance range
- 200 Ω–200 MΩ
- Data hold
- Max / Min
- 2000 counts, temperature
- True RMS / NCV
VC86 multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, non-contact voltage (NCV) detecting, temperature, hFE, Diode and continuity tests; Designed with unit symbol, backlight display, data hold, max value, min value tests, auto ranging switch, auto power off and alarm functions. 2000 counts display

VC836
VC836 True RMS Auto Range Multimeter, Analog Bar, NCV
Auto-range multimeter
- No dial changes
- One-key
- Counts, True RMS, analog bar
- 6000
- Single current range
- 10 A
- Capacitance range
- 60 nF–60 mF
- Frequency range
- 10 Hz–10 MHz
VC836 multimeter, automatically tests DC voltage, AC voltage, AC current, AC current, Resistance, Capacitance, Frequency, Non-contact voltage (NCV) detecting, Duty-cycle, Temperature, Diode and Continuity; Designed with unit symbol, torch lighting, data hold, analog bar display, backlight display, auto ranging switch, auto power and alarm functions. 6000 counts display

VC837A
VC837A True RMS Auto Range Multimeter, Analog Bar, NCV
Auto-range multimeter
- Counts, True RMS, auto range
- 6000
- Trend display under digits
- Analog bar
- DC / AC current range
- 600 μA–10 A
- Capacitance range
- 60 nF–60 mF
- Frequency range
- 10 Hz–10 MHz
VC837A multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Frequency, Non-contact voltage detecting, Duty-cycle, Temperature, Diode and Continuity tests; Designed with unit symbol, backlight display, analog bar display, torch lighting, data hold, auto ranging switch, auto power off and alarm functions. 6000 counts display

VC835A
VC835A True RMS Auto Range Multimeter with NCV
Auto-range multimeter
- Counts, auto ranging
- 2000
- DC / AC current range
- 200 μA–10 A
- Temperature range
- -40–1000 ℃
- Plus torch, backlight
- True RMS / NCV
- HFE transistor test
- 0–2000
VC835A multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Non-contact voltage (NCV), Temperature, hFE, Diode and Continuity tests; Designed with unit symbol, Backlight display, Data hold, Torch lighting, Auto ranging switch, Auto power off and Alarm functions. 1999 counts display

VC837
VC837 6000-Count True RMS Auto Range Multimeter, NCV
Auto-range multimeter
- Counts, True RMS, auto range
- 6000
- DC / AC current range
- 600 μA–10 A
- Capacitance range
- 60 nF–60 mF
- Frequency range
- 10 Hz–10 MHz
- Duty cycle
- 1%–99%
VC837 multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Frequency, Non-contact voltage (NCV) detecting, Duty-cycle, Temperature, Diode and Continuity tests; Designed with unit symbol, Torch lighting, Data hold, Auto ranging switch, Auto power off and alarm functions. 6000 counts display

VC835
VC835 True RMS Auto Range Multimeter with NCV
Auto-range multimeter
- Counts, auto ranging
- 2000
- DC / AC current range
- 200 μA–10 A
- Temperature range
- -40–1000 ℃
- Plus torch, backlight
- True RMS / NCV
- HFE transistor test
- 0–2000
VC835 multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, non-contact voltage detecting, temperature, hFE, Diode and continuity tests; Designed with unit symbol, backlight display, data hold, torch lighting, auto range switch, auto power and alrm functions. 1999 counts display

VC890C
VC890C Manual Range Multimeter with Shockproof Holster
Manual-range multimeter
- DC voltage range
- 200 mV–1000 V
- DC / AC current range
- 20 μA–20 A
- Temperature range
- -40–1000 ℃
- Capacitance range
- 2 nF–200 μF
- Counts, True RMS
- 2000
VC890C multimeter, DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Temperature, Diode and Contunity tests; Designed with unit symbol, data hold, Auto power off and alarm functions. 2000 counts display.

VC890D
VC890D Manual Range Multimeter with Shockproof Holster
Manual-range multimeter
- DC voltage range
- 200 mV–1000 V
- AC voltage range
- 2 V–750 V
- DC current range
- 200 μA–20 A
- Capacitance range
- 20 nF–200 μF
- Counts, True RMS
- 2000
VC890D multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Diode and Continuity tests; Designed with unit symbol , data hold, auto power off and alarm functions. 2000 counts display.

VC9808+
VC9808+ Manual Range Multimeter, Inductance and 2000uF
Manual range multimeter
- Manual range, peak hold
- 2000 counts
- Inductance
- 2 mH–20 H
- Max resistance
- 2000 MΩ
- Max capacitance
- 2000 μF
- Temperature
- -40–1000 ℃
VC9808+ multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Inductance, Frequency, Temperature, hFE, Diode and Continuity tests; Designed with unit symbol, peak value hold, auto power off and protect function for error operation. 2000 counts display.

VC9802A+
VC9802A+ Manual Range Multimeter, 200uF Capacitance
Manual range multimeter
- Manual range
- 2000 counts
- DC voltage, ±(0.5%+3)
- 1000 V DC
- Max resistance
- 200 MΩ
- Max capacitance
- 200 μF
- Max AC/DC current
- 20 A
VC9802A+ multimeter is available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, hFE, Diode anc continuity alarm tests ; Designed with unit symbol, backlight, data hold, auto power off and protection function for error operations. 2000 counts display.

VC833A
VC833A Manual Range Multimeter, True RMS, NCV, Flashlight
Manual-range multimeter
- DC voltage range
- 200 mV–600 V
- DC current range
- 20 μA–10 A
- Counts, manual ranging
- 2000
- AC measurement / live detect
- True RMS / NCV
- Plus backlight, data hold
- Torch
VC833A multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Non-contact voltage detecting, hFE, Diode and continuity alarm tests; Designed with unit symbol, backlight, data hold, torch lighting, auto power off and alarm functions; 2000 counts display.

VC833
VC833 Manual Range Multimeter, True RMS and NCV
Manual-range multimeter
- DC voltage range
- 200 mV–600 V
- DC current range
- 20 μA–10 A
- Counts, manual ranging
- 2000
- AC measurement / live detect
- True RMS / NCV
- HFE transistor test
- 0–2000
VC833 multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Non-contact voltage detecting, hFE, Diode and continuity alarm tests ; Designed with unit symbol, backlight, data hold, auto power off and alarm functions;. 2000 counts display.

VC8045
VC8045 19999-Count Bench Multimeter, True RMS AC+DC
Bench multimeter
- Counts, manual ranging
- 19999
- DCV basic accuracy
- ±(0.05%+1)
- AC measurement
- True RMS AC+DC
- AC frequency response
- 40 Hz–50 kHz
- DC current range
- 20 mA–20 A
This VC8045 bench type multimeter can measure DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Diode, Triode, Continuity and Frequency. AC voltage and current are measured by high-precision true RMS, which has the characteristics of measuring frequency bandwidth, and accurately measure the RMS of any waveform of AC or AC+DC. 19999 counts display.
The table below lists every Vicimeter multimeter with its main functions.
How to Choose Digital Multimeters
Four decisions narrow this list to two or three models.
- Voltage and safety rating: the VC83x models (VC833A, VC835B, VC837, VC836) measures to 600V and is rated CAT III 300V, which suits electronics repair and household circuits. For distribution boards and industrial panels, pick a CAT III 600V model that reads 1000V DC, such as VC86, VC97A, VC99 or VC746A.
- Display resolution: 2000 counts (VC86, VC732A) is enough for mains and battery checks. 6000 counts (VC837, VC99) gives one more digit on low voltages. For component work, VC9807A+ shows 20000 counts with DCV accuracy of ±(0.1%+5), and the mains powered VC8045 bench meter reaches ±(0.05%+1).
- Ranging style: VC836 measures with one key and no dial changes. VC97A, VC99 and VC88 offer both auto and manual range, useful when an auto range meter keeps hunting on a drifting signal. Manual models such as VC890D and VC9802A+ are listed under manual range multimeters.
- Special functions: VC87 has a VSD mode for variable frequency drive outputs, VC88 tests TTL/CMOS logic levels, VC746A adds a live contact voltage test, and VC890C measures temperature to 1000℃. If you only need NCV and a torch on a 600V meter, see the auto range multimeters.
Bench Multimeters
| Model | Key functions |
|---|---|
| VC8045 | Max.19999 counts, High Accuracy Bench Type Multimeter, True RMS, AC +DC measurements, Backlight |
Manual Range Multimeters
| Model | Key functions |
|---|---|
| VC834 | manual range multimeter, True RMS, NCV, temperature, Max/Min data hold |
| VC890C | Manual ranging, Max 200uF capacitance, Anti-high pressure ignition design, high-strength anti-drop protection shock-proof holster. |
| VC890D | Manual ranging, Max 200uF capacitance test, Anti-high pressure ignition design, High-strength anti-drop protection shock-proof holster. |
| VC9808+ | Max 2000uF capacitance, Max 2000MΩ resistance, Inductance, Frequency, Temperature tests, Anti-high pressure ignition design. |
| VC9802A+ | Current 200uA, Max 200uF capacitance, Max 200MΩ resistance, Anti-high pressure ignition design. |
| VC833A | Manual ranging, True RMS, NCV test, Data hold, Backlight, Torch lighting function. |
| VC833 | Manual ranging, True RMS, NCV tests, Data hold, Backlight. |
Auto Range Multimeters
| Model | Key functions |
|---|---|
| VC746A | Live, NCV, T-RMS tests 6000 counts auto ranging multimeter with Data hold, Duty-cycle, Diode, hFE tests and Data hold, Backlight Torch functions |
| VC835B | Max 2000 counts, True RMS & NCV test, Data hold, Backlight, Torch lighting function, 2024 new protect holster. |
| VC89 | auto range multimeter, True RMS, pulse and square wave output, NCV, 6000 counts |
| VC179 | 1000V industrial multimeter, True RMS, 0.09% DCV accuracy, NCV, analog bargraph |
| VC732A | NCV T-RMS Duty-cycle Diode hFE tests digital multimeter with data-hold, backlight, torch functions |
| VC87 | Non-linear True RMS maximum frequency response 10kHz measurement, Frequency conversion measurement, Analog bar display, Max/Min |
| VC99 | True RMS, Analog bar display, NCV test, Max/Min , Data hold, Backlight. |
| VC97A | Max 4000 counts, True RMS, NCV Tests, Max/Min, Data hold, Backlight. |
| VC88 | COMS, TTL logic level tests, Frequency, Duty-cycle, REL, tests, Data hold, Backlight. |
| VC86 | True RMS, NCV tests, Max/Min tests, Data hold, Backlight. |
| VC836 | Intelligent True RMS, NCV tests, Analog bar display, Data hold, Backlight, Torch lighting function. |
| VC837A | True RMS test, Analog bar display, NCV test, Data hold, Backlight, Torch lighting function. |
| VC835A | True RMS, NCV tests, Data hold, Backlight, Torch lighting function. |
| VC837 | Max 6000 counts, True RMS & NCV test, Data hold, Backlight, Torch lighting function. |
| VC835 | True RMS, NCV tests, Data hold, Backlight, Torch lighting function. |
4.5-Digit Multimeters
| Model | Key functions |
|---|---|
| VC9807A+ | Max 19999 counts high accuracy, Max 200uF capacitance, Frequency, Conductance tests, Anti-high pressure ignition design. |
Digital Multimeters Guides
- CAT III vs CAT IV Multimeter: Which Rating You Need
- Multimeter Counts Explained: 2000 vs 6000 vs 20000
- True RMS vs Average Multimeter, Auto vs Manual Range
- Milliohm Meter vs Multimeter: 4-Wire Kelvin Explained
- LCR Meter vs Multimeter: Inductance, Capacitance, ESR
- Insulation Tester vs Multimeter: When Ohms Is Not Enough
- Clamp Meter vs Multimeter: AC and AC/DC Clamp Guide