Megohmmeters and Insulation Resistance Testers
An insulation resistance tester, also called a megohmmeter, applies a high DC test voltage to cables, motors and electrical equipment and measures the leakage resistance in megohms. Vicimeter insulation multimeters combine this test with standard multimeter functions, and several models add polarization index (PI) and dielectric absorption ratio (DAR) for insulation diagnosis.
Models
Max test voltage
Features
FLAGSHIPVC4060PD
VC4060PD 2500V Insulation Multimeter, PI and DAR
Insulation multimeter
- 5 test voltages
- 100–2500 V
- Max insulation resistance
- 50 GΩ
- Timed tests
- PI / DAR
- True RMS display
- 6000 counts
- Non-contact voltage
- NCV
VC4060PD Insulation + Multimeter, 100V/2GΩ-2500V/50GΩ, PI/DAR, True RMS test, NCV test, Data hold, Backlight, Torch lighting functions.
FLAGSHIPVC1508PD
VC1508PD 2500V Insulation Multimeter, Remote Test Lead
Insulation multimeter
- 5 test voltages
- 100–2500 V
- Max insulation resistance
- 50 GΩ
- Timed tests
- PI / DAR
- True RMS display
- 6000 counts
- Remote control test lead
- Remote
VC1508PD Insulation Multimeter with Remote Control Test Leads, supporting five insulation test voltage ranges of 100V/250V/500V/1000V/2500V, with a maximum measurement up to 50GΩ. It is equipped with professional functions such as automatic calculation of PI Polarization Index/DAR Dielectric Absorption Ratio, timed measurement, data hold, and audible and visual alarm, and can monitor the output voltage in real time to avoid misjudgment. It supports true RMS AC/DC voltage, resistance, capacitance, frequency, diode, and continuity testing, as well as NCV non-contact voltage detection. Featuring double insulation protection, auto-ranging, and automatic power-off, it is easy to operate and portable, making it an ideal tool for testing equipment including automobile repair shops, electric motors, transformers, cables, and switchgears.

VC4060PC
VC4060PC Insulation Multimeter
Insulation multimeter
- 5 test voltages
- 50–1000 V
- Max insulation resistance
- 20 GΩ
- Timed tests
- PI / DAR
- True RMS display
- 6000 counts
- Non-contact voltage
- NCV
VC4060PC Insulation + Multimeter, 50V/200MΩ-1000V/20GΩ, PI/DAR, True RMS test, NCV test, Data hold, Backlight, Torch lighting functions.

VC1508PC
VC1508PC 1000V Insulation Multimeter, Remote Test Lead
Insulation multimeter
- 5 test voltages
- 50–1000 V
- Max insulation resistance
- 20 GΩ
- Timed tests
- PI / DAR
- True RMS display
- 6000 counts
- Remote control test lead
- Remote
VC1508PC Remote Control Insulation Multimeter is designed for NEV maintenance and industrial high-voltage detection. It provides 50V/100V/250V/500V/1000V insulation tests, true RMS, auto-ranging and complete electrical measurements. With dual insulation protection, it is ideal for NEV three-electric system and industrial electrical work.

VC1508B+
VC1508B+ Remote Insulation Multimeter, True RMS, NCV
Insulation multimeter
- Insulation test voltages
- 500 / 1000 V
- Max insulation at 1000 V
- 10 GΩ
- Inductance
- 6 mH–100 H
- AC/DC current
- 20 A
- Remote control test lead
- Remote
VC1508B+ Remote Control Insulation Multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Insulation Resistance, Inductance, Capacitance, Frequency, Non-contact voltage detecting, Duty-cycle, Temperature, Diode and Continuity tests; Designed with unit symbol, backlight display, torch lighting, data hold, auto ranging switch, auto power off and alarm functions. 6000 counts display

VC1508AT
VC1508AT Remote Insulation Multimeter, 3-in-1 Megohmmeter
Insulation multimeter
- 3 test voltages
- 250–1000 V
- Max insulation at 1000 V
- 10 GΩ
- AC/DC current
- 20 A
- True RMS display
- 6000 counts
- Remote control test lead
- Remote
VC1508AT Remote Control Insulation Multimeter is designed for NEV maintenance and industrial high-voltage detection. It provides 250V/500V/1000V insulation tests, true RMS, auto-ranging and complete electrical measurements. With dual insulation protection, it is ideal for NEV three-electric system and industrial electrical work.

VC60B+
VC60B+ Insulation Resistance Tester with HV Alarm
Insulation resistance tester
- Test voltages
- 250/500/1000 V
- Max insulation at 1000 V
- 2 GΩ
- Insulation accuracy
- ±(4.0%+2)
- DC voltage
- 0–1000 V
- HV and short-circuit alarm
- Audible/visual
VC60B+ insulation tester, with safety protection high voltage warning, insulation breakdown short circuit alarm, continuous insulation test device for specific environment, accurate and safe for you to use with peace of mind. It can test the insulation resistance between various generators, motors, power sockets, cables, enameled coils, conductors and non-conductors on trains, EMUs, and equipment. 2000 counts display

VC4060A
VC4060A Insulation Multimeter and Motor Checker, True RMS
Insulation multimeter
- Insulation test voltage
- 1000 V
- Max insulation resistance
- 20 GΩ
- AC/DC current
- 20 A
- True RMS display
- 4000 counts
- Temperature
- -40–1000 °C
VC4060A motor checker insulation multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Insulation Resistance, Capacitance, Frequency, Non-contact voltage detecting, Duty-cycle, Temperature, Diode and Continuity tests; Designed with unit symbol, backlight display, torch lighting, data hold, auto ranging switch, auto power off and alarm functions. 4000 counts display

VC4060B
VC4060B Insulation Multimeter with Inductance, True RMS
Insulation multimeter
- Insulation test voltage
- 1000 V
- Max insulation resistance
- 20 GΩ
- Inductance
- 6 mH–100 H
- AC/DC current
- 20 A
- True RMS display
- 6000 counts
VC4060B motor checker insulation multimeter, available to Inductance, DC voltage, AC voltage, DC current, AC current, Resistance, Insulation Resistance, Capacitance, Frequency, Non-contact voltage detecting, Duty-cycle, Temperature, Diode and Continuity tests; Designed with unit symbol, backlight display, torch lighting, data hold, auto ranging switch, auto power off and alarm functions. 6000 counts display

VC4060B+
VC4060B+ Insulation and Inductance Multimeter, True RMS
Insulation multimeter
- Insulation test voltages
- 500 / 1000 V
- Max insulation at 1000 V
- 20 GΩ
- Inductance
- 6 mH–100 H
- AC/DC current
- 20 A
- True RMS display
- 6000 counts
VC4060B+ insulation multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Insulation Resistance, Inductance, Capacitance, Frequency, Non-contact voltage detecting, Duty-cycle, Temperature, Diode and Continuity tests; Designed with unit symbol, backlight display, torch lighting, data hold, auto ranging switch, auto power off and alarm functions. 6000 counts display

VC4060AT
VC4060AT Insulation Multimeter and Motor Checker, True RMS
Insulation multimeter
- 3 insulation test voltages
- 250–1000 V
- Max insulation at 1000 V
- 20 GΩ
- AC/DC current
- 20 A
- True RMS display
- 6000 counts
- Temperature
- -40–1000 °C
VC4060AT insulation multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Insulation Resistance, Capacitance, Frequency, Non-contact voltage detecting, Duty-cycle, Temperature, Diode and Continuity tests; Designed with unit symbol, backlight display, torch lighting, data hold, auto ranging switch, auto power off and alarm functions. 6000 counts display
How to Choose Insulation Testers
Choose by test voltage first, then by how high a reading you need and how you will hold the probes.
- Test voltage: match it to the rated voltage of the equipment and to the procedure you follow. VC4060AT and VC1508AT step through 250V, 500V and 1000V for low voltage cables and motors. VC4060B+ and VC1508B+ offer 500V and 1000V. VC4060PC starts at 50V for telecom and control wiring, and VC4060PD and VC1508PD go up to 2500V.
- Upper resistance limit: healthy insulation on new cable often reads above the meter's ceiling. VC60B+ reads to 2GΩ, the VC4060A/B/AT/B+ models to 20GΩ at 1000V, and the 2500V models to 50GΩ. A higher ceiling lets you see a slow decline over years before it becomes a fault.
- PI and DAR: only the PC and PD versions (VC4060PC, VC4060PD, VC1508PC, VC1508PD) calculate these ratios, so pick one of them for motor and transformer trend records.
- One-handed operation: the VC1508 series comes with a remote control test lead, so you can start the test at the probe while the other hand holds the second clip. This helps on ladders and inside cabinets.
- Dedicated tester or insulation multimeter: VC60B+ is a simple megohmmeter with a high voltage alarm. The insulation multimeters add current to 20A, capacitance and temperature, and VC4060B and VC4060B+ also measure inductance to 100H. Milliohm and earth testers are on the electrical safety testers page.
Insulation Multimeters
| Model | Key functions |
|---|---|
| VC4060PD | Insulation Multimeter |
| VC4060PC | Insulation Multimeter |
| VC1508PC | Insulation Multimeter with Remote Control Test Lead, 1000V Megohmmeter for New Energy Vehicle Maintenance |
| VC1508B+ | Remote Control Insulation Multimeter, True RMS test, NCV test, Data hold, Backlight, Torch lighting, Max/Min and the difference value between max and min. |
| VC1508AT | Remote Control Insulation Multimeter, High-Voltage 3-in-1 Tester & Digital Megohmmeter for New Energy Vehicles |
| VC1508PD | Insulation Multimeter with Remote Control Test Lead, 2500V Megohmmeter for New Energy Vehicle Maintenance |
| VC4060A | Insulation DMM Motor Checker, True RMS test, NCV test, Data hold, Backlight, Torch lighting, Max/Min and the difference value between max and min. |
| VC4060B | Insulation Induction DMM Motor Checker, True RMS test, NCV test, Data hold, Backlight, Torch lighting, Max/Min and the difference value between max and min. |
| VC4060B+ | Insulation Inductance Multimeter, True RMS test, NCV test, Data hold, Backlight, Torch lighting, Max/Min and the difference value between max and min. |
| VC4060AT | Insulation DMM Motor Checker, True RMS test, NCV test, Data hold, Backlight, Torch lighting, Max/Min and the difference value between max and min |
Insulation Resistance Testers
| Model | Key functions |
|---|---|
| VC60B+ | Insulation Resistance Tester, Alarm for High voltage, Audible & Visual Alarm for short circuit, AC voltage, Resistance, Continuity tests. |
Insulation Testers Videos
Insulation Testers Guides
- Insulation Tester vs Multimeter: When Ohms Is Not Enough
- Insulation Tester vs Megger: How to Choose Test Voltage
- Fluke 1508 Insulation Tester vs VC1508PD and VC4060PD
- How to Test EV High-Voltage System Insulation Resistance
- How to Test Motor Windings for Resistance and Insulation
- VC1508PD Insulation Multimeter Operation Guide, Step by Step
- PI and DAR Explained: Insulation Diagnosis for Equipment