VC97A 4000-Count True RMS Auto Range Multimeter, NCV
Auto range multimeter

VC97A 4000-Count True RMS Auto Range Multimeter, NCV

VC97A Max 4000 counts, True RMS, NCV Tests, Max/Min, Data hold, Backlight.

Auto or manual range
4000 counts
DC voltage, ±(0.5%+5)
1000 V DC
Max AC/DC current
20 A
Max capacitance
40 mF
NCV, Max/Min, REL
True RMS
Safety rating
CAT III 600 V

Fits

  • Electrical maintenance up to 1000 V DC and 20 A
  • Electronics repair: capacitance, frequency to 10 MHz and duty cycle
  • HVAC service with temperature from -40 ℃ to 1000 ℃

Factory direct. OEM labelling and distributor pricing on request.

VC97A Overview

VC97A multimeter, available to  DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, non-contact voltage detection, duty cycle, temperature, diode and continuity tests; Designed with unit symbol display and maximum and minimum value measurement, data hold, auto ranging switch, auto power off and alarm functions.
4000 counts display

The VC97A is the 4000-count model of the VC98 auto-range series. It measures DC voltage to 1000V at ±(0.5%+5) and current to 20A, and adds capacitance up to 40mF, frequency to 10MHz, duty cycle and temperature. NCV, True RMS, Max/Min data hold and REL measurement are included, and ranging can be automatic or manual.

Key features

  • 4000 counts, auto range or manual range
  • DCV 400mV to 1000V ±(0.5%+5); ACV 4V to 750V ±(0.8%+10)
  • DCA and ACA 400μA to 20A; resistance 400Ω to 40MΩ ±(0.8%+2)
  • Capacitance 40nF to 40mF ±(2.5%+5), frequency 10Hz to 10MHz, duty cycle, temperature -40℃~1000℃ ±(1.0%+5)
  • True RMS, NCV, Max/Min data hold, REL, backlight
  • Diode, hFE and continuity (below about 30Ω) tests, anti-shock protection, two AAA cells; safety rating CAT.III 600V

Applications

Electrical maintenance up to 1000V DC, electronics repair and HVAC service with temperature.

Choosing within the series

The VC98 auto-range series has three models with the same housing and Max/Min, REL and duty cycle functions. The VC97A is the 4000-count model without an analog bar. The VC99 has the same function set at 6000 counts, adds an analog bar display, and extends capacitance to 60mF. The VC87 also has 6000 counts and an analog bar, adds VSD voltage measurement for variable frequency drives and frequency to 30MHz, but has no NCV.

VC97A Specifications

Technical Data:

Basic function

Range

Basic accuracy

DCV

400mV/4V/40V/400V/1000V

±(0.5%+5)

ACV

4V/40V/400V/750V

±(0.8%+10)

DCA

400uA/4000uA/40mA/400mA/4A/20A

±(1.0%+5)

ACA

400uA/4000uA/40mA/400mA/4A/20A

±(1.5%+10)

Resistance

400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ

±(0.8%+2)

Capacitance

40nF/400nF/ /4uF/40uF/400uF/4mF/40mF

±(2.5%+5)

Frequency

10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz

±(0.5%+4)

Temperature

-40℉ ~ 1832℉

±(1.0%+5)

-40℃ ~ 1000℃

±(1.0%+5)


Special Function:

Model

VC97A

True RMS

Yes

NCV Function

Yes

Backlight display

Yes

Diode test

Yes

hFE test

Yes

Continuity test

Approx. less than 30Ω

Low battery indication

Approx less than 2.4V

Duty cycle measuring

Yes

Data hold

MAX, MIN,DATA HOLD

Auto power off

Approx.15minutes

Function protection

Yes

Input impendence

10MΩ

Sampling rate

3times/s

AC frequency response

40-2kHz

Operation way

Manual or auto range

Max. display

4000

LCD size

65x41mm

Battery

2 X 1.5 AAA

Power consumption

Quiescent current approx. 2mA

Compare models in the series

 VC97AVC99VC87
Max display400060006000
Analog barNoYesYes
NCVYesYesNo
VSD voltageNoNo6–750 V
Max capacitance40 mF60 mF2000 μF
Max frequency10 MHz10 MHz30 MHz

VC97A Downloads and Guides

More Auto Range Multimeters

Need a quote or sample for the VC97A?

Factory direct. OEM labelling and distributor pricing on request.