Manual Range Multimeters for Everyday Electrical Testing
Manual range multimeters let the user set the range on the rotary switch. They respond quickly, are simple to operate and suit routine electrical, electronics and teaching work.
Models

VC834
VC834 True RMS Manual Range Multimeter, NCV, Temperature
Manual-range multimeter
- DC voltage range
- 200 mV–600 V
- Temperature range
- -40–1000 ℃
- Data hold
- Max / Min
- AC measurement / live detect
- True RMS / NCV
- Counts, manual ranging
- 2000
VC834 manual range multimeter measures DC voltage, AC voltage, DC current, resistance and temperature, with diode and continuity tests. It has True RMS, non-contact voltage (NCV) detection, backlight, Max/Min data hold, protection and anti-shock function, low battery indication and auto power off. 2000 counts display, powered by two AAA batteries.

VC890C
VC890C Manual Range Multimeter with Shockproof Holster
Manual-range multimeter
- DC voltage range
- 200 mV–1000 V
- DC / AC current range
- 20 μA–20 A
- Temperature range
- -40–1000 ℃
- Capacitance range
- 2 nF–200 μF
- Counts, True RMS
- 2000
VC890C multimeter, DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Temperature, Diode and Contunity tests; Designed with unit symbol, data hold, Auto power off and alarm functions. 2000 counts display.

VC890D
VC890D Manual Range Multimeter with Shockproof Holster
Manual-range multimeter
- DC voltage range
- 200 mV–1000 V
- AC voltage range
- 2 V–750 V
- DC current range
- 200 μA–20 A
- Capacitance range
- 20 nF–200 μF
- Counts, True RMS
- 2000
VC890D multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Diode and Continuity tests; Designed with unit symbol , data hold, auto power off and alarm functions. 2000 counts display.

VC9808+
VC9808+ Manual Range Multimeter, Inductance and 2000uF
Manual range multimeter
- Manual range, peak hold
- 2000 counts
- Inductance
- 2 mH–20 H
- Max resistance
- 2000 MΩ
- Max capacitance
- 2000 μF
- Temperature
- -40–1000 ℃
VC9808+ multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Inductance, Frequency, Temperature, hFE, Diode and Continuity tests; Designed with unit symbol, peak value hold, auto power off and protect function for error operation. 2000 counts display.

VC9802A+
VC9802A+ Manual Range Multimeter, 200uF Capacitance
Manual range multimeter
- Manual range
- 2000 counts
- DC voltage, ±(0.5%+3)
- 1000 V DC
- Max resistance
- 200 MΩ
- Max capacitance
- 200 μF
- Max AC/DC current
- 20 A
VC9802A+ multimeter is available to DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, hFE, Diode anc continuity alarm tests ; Designed with unit symbol, backlight, data hold, auto power off and protection function for error operations. 2000 counts display.

VC833A
VC833A Manual Range Multimeter, True RMS, NCV, Flashlight
Manual-range multimeter
- DC voltage range
- 200 mV–600 V
- DC current range
- 20 μA–10 A
- Counts, manual ranging
- 2000
- AC measurement / live detect
- True RMS / NCV
- Plus backlight, data hold
- Torch
VC833A multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Non-contact voltage detecting, hFE, Diode and continuity alarm tests; Designed with unit symbol, backlight, data hold, torch lighting, auto power off and alarm functions; 2000 counts display.

VC833
VC833 Manual Range Multimeter, True RMS and NCV
Manual-range multimeter
- DC voltage range
- 200 mV–600 V
- DC current range
- 20 μA–10 A
- Counts, manual ranging
- 2000
- AC measurement / live detect
- True RMS / NCV
- HFE transistor test
- 0–2000
VC833 multimeter, available to DC voltage, AC voltage, DC current, AC current, Resistance, Non-contact voltage detecting, hFE, Diode and continuity alarm tests ; Designed with unit symbol, backlight, data hold, auto power off and alarm functions;. 2000 counts display.
The models below cover voltage, current, resistance and common extra functions.
Compare Manual Range Multimeters
| Model | Key functions |
|---|---|
| VC834 | manual range multimeter, True RMS, NCV, temperature, Max/Min data hold |
| VC890C | Manual ranging, Max 200uF capacitance, Anti-high pressure ignition design, high-strength anti-drop protection shock-proof holster. |
| VC890D | Manual ranging, Max 200uF capacitance test, Anti-high pressure ignition design, High-strength anti-drop protection shock-proof holster. |
| VC9808+ | Max 2000uF capacitance, Max 2000MΩ resistance, Inductance, Frequency, Temperature tests, Anti-high pressure ignition design. |
| VC9802A+ | Current 200uA, Max 200uF capacitance, Max 200MΩ resistance, Anti-high pressure ignition design. |
| VC833A | Manual ranging, True RMS, NCV test, Data hold, Backlight, Torch lighting function. |
| VC833 | Manual ranging, True RMS, NCV tests, Data hold, Backlight. |
Manual Range Multimeters Guides
- True RMS vs Average Multimeter, Auto vs Manual Range
- CAT III vs CAT IV Multimeter: Which Rating You Need
- Multimeter Counts Explained: 2000 vs 6000 vs 20000
- Clamp Meter vs Multimeter: AC and AC/DC Clamp Guide
- Beginner's Guide to Using a Multimeter: Common Mistakes
- Milliohm Meter vs Multimeter: 4-Wire Kelvin Explained
- LCR Meter vs Multimeter: Inductance, Capacitance, ESR
- Insulation Tester vs Multimeter: When Ohms Is Not Enough