CM-2018 800A AC/DC Clamp Meter, LoZ, LPF, True RMS
AC/DC clamp meter

CM-2018 800A AC/DC Clamp Meter, LoZ, LPF, True RMS

CM-2018 Clamp open 28mm, AC DC Max 800A, LPF, LoZ V, True RMS, NCV (clamp + red test lead), Capacitance, Frequency, Temperature tests, Backlight, Clamp lighting function.

Current, True RMS
AC/DC 800 A
Counts display
6000
Low-Z and VFD voltage
LoZ / LPF
Clamp opening
28 mm
Capacitance
6 nF–60 mF
Safety rating
CAT III 600 V

Fits

  • VFD and inverter-driven motor circuits, HVAC with variable-speed compressors
  • Solar and battery systems, and wiring checks where induced voltage gives false readings

Factory direct. OEM labelling and distributor pricing on request.

CM-2018 Overview

CM-2018 clamp meter, available to DC voltage, AC voltage, DC current, AC current, LPF, LoZ V, resistance, capacitance, frequency, non-contact voltage (clamp + red test lead 2 detecting ways), temperature, diode and continuity tests; Designed with unit symbol and backlight display, data hold, clamp lighting, auto ranging switch, auto power off and alarm functions.
    6000 counts display

The CM-2018 is a 6000-count True RMS AC/DC clamp meter for motor drive work. On top of 800A AC and DC current at ±(1.5%+5), it adds LoZ low-impedance voltage (0V to 600V AC and DC, ±(2.0%+10)), and LPF low-pass filtered AC voltage (0V to 600V, ±(4.0%+8)) for VFD outputs. The 28mm jaw has a clamp light.

Key features

  • DC and AC current 60A to 800A, ±(1.5%+5)
  • LoZ voltage 0V to 600V AC/DC, ±(2.0%+10); LPF voltage 0V to 600V, ±(4.0%+8)
  • DC voltage 600mV to 600V, ±(0.5%+5); AC voltage 6V to 600V, ±(0.8%+5)
  • Capacitance 6nF to 60mF, frequency 10Hz to 10MHz, duty cycle, temperature -40℃ to 1000℃
  • Orange backlight alarm for high voltage, NCV by jaw and red test lead, clamp light, data hold
  • Safety rating CAT.III 600V

Applications

VFD and inverter-driven motor circuits, industrial maintenance, HVAC with variable-speed compressors, solar and battery systems, and wiring checks where induced voltage gives false readings.

Choosing within the series

The CM-2018 is the upper model of the CM20 series. Against the CM-2016 it adds LoZ, LPF, the orange high-voltage backlight alarm and a second NCV method through the red test lead. Current, resistance, capacitance, frequency and temperature ranges are the same on both. The CM-2016 has slightly tighter AC voltage accuracy, ±(0.5%+5). Choose the CM-2018 if you measure drive outputs or need LoZ.

CM-2018 Specifications

Technic Data:

Basic function

Range

Accuracy

DCV

600mV/6V/60V/600V

±(0.5%+5)

LoZ 0V~600V

±(2.0%+10)

ACV

6V/60V/600V

±(0.8%+5)

LPF 0V ~ 600V

±(4.0%+8)

LoZ 0V ~ 600V

±(2.0%+10)

DCA

60A/600A/800A

±(1.5%+5)

ACA

60A/600A/800A

±(1.5%+5)

Resistance

600Ω/6KΩ/60KΩ/600KΩ/6MΩ/60MΩ

±(0.8%+1)

Capacitance

6nF/60nF/600nF/6uF/60uF/600uF/6MF/60MF

±(2.5%+5)

Frequency

10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz

±(0.5%+4)

Temperature

(-40 to 1000 )℃, (-40 to 1832 ) ℉

±(1.0%+5)


Special Function:

Model

CM-2018

Diode test

Yes

Continuity test

Less than 50Ω

LoZ V function

Yes

Low battery indicator

Approx. less than 2.6 V

Data hold

Yes

NCV

√ (2 detecting way)

Auto power off

About 15 minutes

True RMS test

Yes

LPF function

Yes

Function protection

Yes

Clamp light function

Yes

Backlight display

Yes

Input impedance

10MΩ

Sampling rate

3 times/s

AC frequency response

40-2kHz

Operation method

Auto or manual range

Max display

6000

Clamp opens

28mm

Battery

3V (2*AAA battery)

Compare models in the series

 CM-2018CM-2016
AC/DC current800 A800 A
LoZ voltageYesNo
LPF voltageYesNo
NCV detectionJaw + red leadJaw
AC voltage accuracy±(0.8%+5)±(0.5%+5)

CM-2018 Downloads and Guides

More AC/DC Clamp Meters

Need a quote or sample for the CM-2018?