CM-2007 800A True RMS AC Clamp Meter, Capacitance, Temp
AC clamp meter

CM-2007 800A True RMS AC Clamp Meter, Capacitance, Temp

CM-2007 28mm clamp open, 800A True RMS, Capacitance Frequency, Temperature, NCV tests, Backlight, Clamp lighting function.

AC current, True RMS
800 A
Counts display
4000
Clamp opening
28 mm
Capacitance
4 nF–40 mF
Temperature
-40–1000 °C
Safety rating
CAT III 600 V

Fits

  • HVAC and motor circuits where current runs above 400 A
  • Maintenance teams checking capacitors and temperature on the same job
  • Building and panel electrical work

Factory direct. OEM labelling and distributor pricing on request.

CM-2007 Overview

CM-2007 clamp meter, available to DC voltage, AC voltage, AC current, resistance, capacitance, frequency, non-contact voltage, temperature, diode and continuity tests; Designed with unit symbol and backlight display, data hold, clamp lighting, auto ranging switch, auto power and alarm functions.
4000 counts display

The CM-2007 is a 4000-count True RMS AC clamp meter with a 28mm jaw. It is the only model in the CM2000 600A/800A AC series that reaches 800A AC, on ranges of 4A/40A/400A/800A with ±(2.0%+5) accuracy, and it also measures capacitance, frequency and temperature.

Key features

  • AC current 4A to 800A, ±(2.0%+5); DC voltage 400mV to 600V, ±(0.5%+5); AC voltage 4V to 600V, ±(1.0%+5)
  • Resistance 400Ω to 40MΩ, ±(0.8%+3); capacitance 4nF to 40mF, ±(2.5%+5)
  • Frequency 10Hz to 10MHz, duty cycle, and temperature from -40℃ to 1000℃ (-40℉ to 1832℉), ±(1.0%+5)
  • NCV detection, diode test, continuity alarm below about 50Ω, relative (REL) measurement
  • Clamp light, backlight, data hold, auto or manual range, auto power off after about 15 minutes
  • Safety rating CAT.III 600V

Applications

Building and panel electrical work, HVAC and motor circuits where current runs above 400A, and maintenance teams that check capacitors and temperature on the same job.

Choosing within the series

CM-2000B and CM-2000C are 2000-count meters with 600A AC and Max/Min hold; the B adds a 20V battery test and the C adds temperature. CM-2000D and CM-2000E share the CM-2007's 4000-count display but stop at 400A AC. The CM-2000E is the closest sibling, with capacitance only to 4mF. Choose the CM-2007 when you need 800A or capacitance up to 40mF.

CM-2007 Specifications

Technical Data:

Basic function

Range

Accuracy

DCV

400mV/4V/40V/400V/600V

± (0.5%+5)

ACV

4V/40V/400V/600V

±(1.0%+5)

ACA

4A/40A/400A/800A

±(2.0%+5)

Resistance

400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ

±(0.8%+3)

Capacitance

4nF/40nF/400nF/4uF/40uF/400uF/4mF/40mF

±(2.5%+5)

Frequency

10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz

±(0.5%+5)

Temperature

-40℃ to 1000℃  | -40 to 1832℉

±(1.0%+5)

Special Function:

Model

CM-2007

NCV, TRMS

Yes

Diode test

Yes

Continuity alarm

Less than 50 Ω

Low battery indication

Less than 2.4 V

Data hold

Yes

Auto power off

Approx. 15minutes

Function protection

Yes

Clamp light display

Yes

Backlight display

Yes

Input impedance

10MΩ

Sampling rate

3 times/s

AC frequency response

Current (40 to 1000) Hz, Voltage (40 to 2000) Hz

Operation method

Auto or manual range

Max. display

4000

Clamp open

28mm

Power source

3V (2pcs #7 batteries)

Compare models in the series

 CM-2000BCM-2000CCM-2000DCM-2000ECM-2007
Max AC current600 A600 A400 A400 A800 A
Max display (counts)20002000400040004000
Battery test20 V––––
Temperature–-40–1000 °C–-40–1000 °C-40–1000 °C
Capacitance–––4 nF–4 mF4 nF–40 mF

CM-2007 Downloads and Guides

Downloads

Technical Guides Using the CM-2007

More Clamp Meters

Need a quote or sample for the CM-2007?