CM-2000D 400A True RMS AC Clamp Meter, NCV
AC clamp meter

CM-2000D 400A True RMS AC Clamp Meter, NCV

CM-2000D 28mm clamp open, 400A, True RMS, NCV, Backlight, Clamp lighting function.

AC current, True RMS
400 A
Counts display
4000
Clamp opening
28 mm
Max resistance
40 MΩ
Non-contact V, relative
NCV / REL
Safety rating
CAT III 600 V

Fits

  • Household and light commercial wiring, socket and lighting circuits
  • Routine current checks on loads up to 400A inside crowded distribution boards

Factory direct. OEM labelling and distributor pricing on request.

CM-2000D Overview

CM-2000D clamp meter, available to DC voltage, AC voltage, AC current, resistance, non-contact voltage, diode and continuity tests; Designed with unit symbol and backlight display, data hold, clamp lighting, auto ranging switch, auto power and alarm functions.  
4000 counts display

The CM-2000D is a 4000-count True RMS AC clamp meter for everyday electrical checks. It measures AC current to 400A on 4A/40A/400A ranges with ±(2.0%+5) accuracy, plus AC and DC voltage to 600V and resistance to 40MΩ. The 28mm jaw, clamp light and backlight make it practical inside crowded distribution boards.

Key features

  • AC current 4A/40A/400A, ±(2.0%+5)
  • DC voltage 400mV to 600V, ±(0.5%+5); AC voltage 4V to 600V, ±(1.0%+5)
  • Resistance 400Ω to 40MΩ, ±(0.8%+3)
  • NCV detection, diode test, continuity alarm below about 50Ω, relative (REL) measurement
  • Data hold, clamp light and backlight, auto or manual range, 10MΩ input impedance, auto power off after about 15 minutes
  • Safety rating CAT.III 600V

Applications

Household and light commercial wiring, socket and lighting circuits, and routine current checks on loads up to 400A. It suits distributors who need a low-cost True RMS clamp with a 4000-count display.

Choosing within the series

The CM-2000D is the core-function model of the 4000-count group in the CM2000 series. The CM-2000E keeps the same ranges and adds capacitance (4nF to 4mF), frequency, duty cycle and temperature. The CM-2007 adds the same extras and raises AC current to 800A with capacitance to 40mF. CM-2000B and CM-2000C have 2000-count displays and 600A AC range. Pick the CM-2000D when voltage, current, resistance and NCV are all the job needs.

CM-2000D Specifications

Basic Function

Range

Accuracy

DCV

400mV/4V/40V/400V/600V

±(0.5%+5)

ACV

4V/40V/400V/600V

±(1.0%+5)

ACA

4A/40A/400A

±(2.0%+5)

Resistance

400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ

±(0.8%+3)

Special Function

CM-2000D

Max. display

4000

Operation method

Auto/Manual range

NCV test

Yes

True RMS test

Yes

Clamp light/Backlight

Yes

Diode test

Yes

REL value test

Yes

Continuity alarm

Approx. less than 50Ω

Data Hold

Yes

Function protection

Yes

Low battery indication

Approx. less than 2.4V

Function protection

10MΩ

Auto power off

Approx. 15minutes

Sampling rate

3 times/s

AC frequency response

40Hz~2kHz

Power supply

3V(2×1.5V AAA)

QTY (pcs/ctn)

40

Safety Rating

CAT.III 600V

Compare models in the series

 CM-2000BCM-2000CCM-2000DCM-2000ECM-2007
Max AC current600 A600 A400 A400 A800 A
Max display (counts)20002000400040004000
Battery test20 V––––
Temperature–-40–1000 °C–-40–1000 °C-40–1000 °C
Capacitance–––4 nF–4 mF4 nF–40 mF

CM-2000D Downloads and Guides

Technical Guides Using the CM-2000D

More Clamp Meters

Need a quote or sample for the CM-2000D?